1.5.17 LT3000 Series

LT3200/3300 Series

LT-3201A

LT-3300L

LT-3300S

LT-3300T

LT-3301L

 

Display Unit

         

 

Screen Area (Unit: byte)

6M

6M

6M

6M

6M

6.5 Font Settings Guide

Portrait Installation

-

3.9.1.1 New - Display Unit and Model Settings

Function Expansion Memory

-

-

-

-

-

5.4.7 System Settings [Display Unit] - [Extended] Settings Guide

Installing the USB/RS-422/485 Conversion Adapters

-

-

-

-

-

7.9.1 System Settings [Device/PLC] Settings Guide

MAC Address Display

-

-

M.17.2.7 Main Unit - Ethernet settings

External Storage

         

 

CF Card

-

-

-

-

-

5.7 Usable External Storage

SD Card

-

-

-

-

-

CFast Card

-

-

-

-

-

USB storage

FTP server

-

-

-

-

-

System Settings

         

 

Drawing in 256 colors

-

-

-

1.6 Supported Colors

Reverse Display

-

-

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

Faded Color Blink

-

-

-

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

Synchronize Text Display with Text Table

-

-

-

-

-

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

Time Zone Settings

-

-

-

-

-

5.4.2 System Settings [Display Unit] - [Display] Settings Guide

Detect Backlight Burnout

5.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Dimmer settings

-

-

-

-

-

5.4.2.1 Display Unit [Display] - Screen Settings

2 point touch / Multitouch

-

-

-

-

-

5.4.3 System Settings [Display Unit] - [Operation] Settings Guide

Display the SD/USB Removal Icon

-

-

-

-

-

5.4.4.4 Display Unit [Mode] - Memory Card Settings

Screen Capture

-

42.6 Saving the Current Screen At Runtime (Screen Capture)

SRAM Auto Backup

-

-

-

-

-

5.4.4.4 Display Unit [Mode] - Memory Card Settings

Image Font

-

-

-

-

-

6.3 Image Font

Bitmap Font

-

-

-

-

-

6.4 Bitmap Font

Standard Font

-

-

-

-

-

5.4.7 System Settings [Display Unit] - [Extended] Settings Guide

Device/PLC Communication*1

         

 

Number of Devices/PLCs that can communicate simultaneously

-

1 *2

1 *2

1 *2

1 *2

7.2 Connecting to Multiple Devices/PLCs

Specify Indirect Device

-

*3

*3

*3

*3

7.9.1 System Settings [Device/PLC] Settings Guide

Import Device/PLC tags

-

-

-

-

-

7.8 Using Device/PLC Tags

Ethernet Multilink

-

-

-

-

-

7.6 Connecting Multiple Display Units to One Device/PLC (Ethernet Multilink)

Device Monitor

-

42.4 Monitoring the Value of Device Addresses (Device Monitor)

Ladder Monitor

-

-

-

-

-

"PLC Ladder Monitor Operation Manual"

Transfer

         

 

Network Transfer

-

-

34.3 Transferring Project Files via Ethernet (LAN)

Modem Transfer

34.9 Updating Remote Screen Data via Modem

SIO Transfer (COM Connection)

34.12.1.1 Transfer Settings

Memory loader feature

34.8 Transferring Project Files Using a CF Card or USB Storage

CF/SD Card Connection

-

-

-

-

-

34.6 Transferring Just Data to a CF/SD Card

Common Settings

         

 

Change Backlight Color

-

-

-

-

5.5.3 Common - Backlight Color Settings

Clock Update Settings

-

-

-

-

-

5.5.2 Common - Clock Update Settings

Start Screen Settings

-

-

-

-

-

5.5.4 Common Settings - Start Screen Settings

Date format on CSV file output

-

-

-

-

-

20.12.1.1 Alarm Guide

25.11.4 Display/Save in CSV

Divide destination folders by file numbers

-

-

-

-

-

5.7.1 Destination Folder and File Name

Increase Alarm Type [Extended] settings and Text Table index numbers

-

-

-

-

-

20.12.1 Common Settings (Alarm) Settings Guide

18.7.1.1 Text Table Settings

Alarm Message Multiple Line Display

-

-

-

-

-

20.12.1.1 Alarm Guide

Attach Data Value to Operation Log

-

-

-

-

-

23.10.2 Operation Log Settings

Changing passwords at run time (CSV file)

-

-

-

-

-

23.8 Editing Passwords Online

Changing passwords at run time (password change screen)

-

-

-

-

-

Append Date/Time to sampling CSV file name

-

-

-

-

-

25.11.4 Display/Save in CSV

Transfer sampling CSV file to FTP

-

-

-

-

-

25.11.4 Display/Save in CSV

Transferring Sampled Data to the Cloud

-

-

-

-

-

25.11.2.3 Mixed Address Settings and Random Data Formats

Indirectly specify Sampling Frequency and Alarm Settings

-

-

-

-

-

25.11.3 Mode

25.11.4.3 Display/Save in CSV/Data Settings - Alarm

Sampling data/Enhanced recipe data format co-exist

-

-

-

-

-

25.6 Collecting, Searching, and Sorting Various Data

Create a recipe (CSV data) index file at runtime

-

-

-

-

-

A.2.2.2 Word Type - #H System Variables

Enhanced Recipes

-

-

-

-

-

26.18 Enhanced Recipe Data Flow

Extended Script copy file function

-

-

-

-

-

22.11.6 File Operation

Global Trigger

-

-

-

-

-

5.5.1 Common Settings - Global Trigger Settings

Movie record/play feature

-

-

-

-

-

28.3 Recording Video

Use image unit

-

-

-

-

-

28.6 Displaying Multiple Video Camera Outputs Simultaneously

Sound Output Feature

-

-

-

-

-

27.1 Settings Menu

AUX

-

-

-

-

-

27.4 Triggering a Buzzer Sound from the Display Unit

Retentive Variables Function

30.3.2.4 Retentive Variable Settings

Parts

         

 

Selector List

-

-

-

-

-

10.16 Selector List Parts Settings Guide

XY Graph

-

-

-

-

-

19.9 Displaying Sampled Data in a Scatter Graph

19.11 Displaying Current Values of Multiple Addresses All at Once in a Scatter Graph

Picture Display [CF Image Display]/[SD Image Display] for showing JPEG files

-

-

-

-

-

9.6.4 CF Image Display/SD Image Display

Indirectly specify a block of Alarm parts

-

-

-

-

-

20.12.2.1 Show History - Basic Settings/Basic

Special Data Display [File Manager] sort function and default path

-

-

-

-

-

26.9.3.2 File Manager - Extended

Special Data Display Part [File Manager] copy file to FTP

-

-

-

-

-

26.9.3.1 File Manager - Basic

Message Display's Bulletin Message

-

-

-

-

-

17.5 Displaying the Same Message on Multiple Display Units (Bulletin Messages)

Image Sensor Display

-

-

-

-

-

28.9 Displaying Video Images of Image Sensor

Animation

-

-

-

-

-

21.1 Animation - General

Alarm History Message Flow Display

-

-

-

-

-

20.12.2.6 Show History - Display

Alarm History/Sampling Data/Enhanced Recipe Data Refine Search/Sort Function

-

-

-

-

-

20.10 Searching / Sorting Alarm History

25.6 Collecting, Searching, and Sorting Various Data

26.23 Searching and Sorting Enhanced Recipe Data

Alarm Analysis Function

-

-

-

-

-

20.11 Alarm Analysis for Operation Log and Sampling

Logic*4

         

 

Logic Program Operation

30.2.1 Using Logic Function

I/O Driver

31.1 Controlling External I/O

Function Block

30.8 Function Block (FB)

Network

         

 

RPA Function

-

-

-

-

-

36.1.1 Remote PC Access (RPA)

GP-Viewer EX

-

-

37.1.1 GP-Viewer EX

Web Server

-

-

-

-

-

37.6.1 Web Server

Camera-Viewer EX

-

-

-

-

-

37.14.1 Camera-Viewer EX

Pro-face Remote HMI

-

-

-

-

-

37.18.1.6 Remote Viewer - Pro-face Remote HMI

GP Remote Printer Server

-

-

35.3.4 Procedure - Printing to a Network Printer

Pro-face Connect (Models you can register as SiteManager)

-

-

-

-

-

42.10 Using Pro-face Connect's System

Input Equipment/Peripheral Equipment (USB Device)

         

 

USB Keyboard

16.3 Display Inputs from USB Keyboard/EZ Numpad

EZ Illuminated Switch

-

-

-

-

-

16.4 Monitoring/Operating Alarm with EZ Illuminated Switch

EZ Tower Light

-

-

-

-

-

Cockpit parts are listed on the Pro-face support site*5

EZ Numpad

-

-

-

-

-

16.3 Display Inputs from USB Keyboard/EZ Numpad

16.5 Setting Up Functions on the EZ Numpad

EZ Fingerprint Recognition Unit

-

-

-

-

-

23.9 Logging in with Fingerprint Recognition

EZ LAN Adapter

-

-

-

-

-

M.17.2.7 Main Unit - Ethernet settings

*1 Depends on the type of connected PLC/Device.

*2 GP-Pro EX Ver.3.1 or later is required in order to communicate with devices/PLCs.

*3 Indirect device occupies 1 MB of the Screen Area.

*4 Cannot use with USB-Serial (RS-232C) conversion cable.

*5 http://www.pro-face.com/trans/en/manual/1001.html