7.9.1 System Settings [Device/PLC] Settings Guide

Set the details of a device/PLC.

Add Device/PLC

Adds the device/PLC settings. Use this setting when one display is communicating with multiple devices/PLCs.

Select [Manufacturer], [Series], and [Port].

Delete Device/PLC

Deletes the specified device/PLC.

Change Device/PLC

Changes the settings of the device/PLC.

7.9.1.1 Change Device/PLC Settings Guide

Summary

Displays the settings of the currently specified devices/PLCs.

Manufacturer

Displays the currently specified device/PLC maker.

Series

Displays the series of the currently set PLC.

Port

Displays the ports that can be connected to a device/PLC.

  • If the port is also used for other devices/PLCs, is displayed to the right of the [Port].

Text Data Mode

Displays the text data mode of the currently specified devices/PLCs.

Change

When the [Change Text Data Mode] dialog box is displayed, you can change the text data mode. Normally the text data mode is specified according to each device/PLC.

  • The USR memory storage order is fixed to [Text Data Mode] = 2, regardless of the actual setting of Text Data Mode.

Data in Device Addresses

Select the data device storage order from [Store from Top Data] or [Store from Last Data].

Storing the text "ABCDE"

  • Store from Start Data

When [Text Data Mode]=1

  • Store from Last Data

When [Text Data Mode]=3

LH/HL Storage

Select the data storage order in one word (16 bits), from either [LH Order] or [HL Order].

Storing the text "ABCDE"

  • HL Order

When [Text Data Mode]=1

  • LH Order

When [Text Data Mode]=2

Double Word LH/HL Storage

Select the data storage order in two words (32 bits), from either [LH Order] or [HL Order].

Storing the text "ABCDE"

  • HL Order

When [Text Data Mode]=1

  • LH Order

When [Text Data Mode]=5

Text Data Mode

Displays the number associated with the Text Data Mode storage order.

Select

Select the text data mode to be used.

Communication Settings

Configure the settings according to the device/PLC.
For the settings, refer to the "GP-Pro EX Device/PLC Connection Manual".

Device-Specific Settings

Set this according to each device/PLC.

Allowable Number of Devices/PLCs

Displays the number of connectable units according to the type of the display unit specified.

Add Device

Each time you click the [Add Device], one device/PLC is added.

  • You cannot add the PLC if the [Allowable Number of Devices/PLCs] or the maximum number of sockets is reached the limit or if the total of PLCs and indirect devices is set up to 128.

Increase Allowable Number of Devices/PLCs

Displayed when you select devices/PLCs for which the number of allowable devices can be expanded. Click this button and the [Increase Allowable Number of Devices/PLCs] dialog box appears.

  • The number of connectable units can be expanded to 64 when the [Increase allowable number of Devices/PLCs] check box is selected.

Delete Device/PLC

Deletes the device/PLC settings.

Device Name

Set the name of a device/PLC characters from 20 to 10 (single-byte).

  • Do not duplicate the device name.

  • The name cannot include a space or any of the following symbols.
    + - * / = % & ^ | \ : . , ” # ? @ [ ] < >

Device/PLC Settings

Set individual settings as needed according to the device/PLC. Click the button to display the [Individual Device Settings] dialog box.

  • The [Individual Device Settings] differ depending on the PLC. For details on the settings of the device/PLC, see "GP-Pro EX Device Connection Manual."

Device ID

When using Indirect Device, and the series in the [Individual Device Settings] dialog box match the device/PLC, use this field to identify the device from 1 to 128.

Make sure you do not duplicate the Device ID with other indirect devices in the same driver. If the Device ID is duplicated, the warning icon appears beside the field.

Add Indirect Device

Set up the Indirect Device feature. Click this button to add a new indirect device to the list. You can add up to 64 indirect devices.

  • You can add up to a total 128 devices/PLCs and indirect devices to a single driver. However, the allowable number of devices/PLCs varies depending on the driver.

Indirect Device Name

Set the name of the indirect device with up to 20 single-byte characters (or 10 double-byte characters).

  • Do not duplicate device names.

  • The name cannot include a space or any of the following symbols.
    + - * / = % & ^ | \ : . , ” # ? @ [ ] < >

Device ID Address

When using indirect devices, the value in the Device ID Address identifies the device ID of the device/PLC to communicate with. You can only use the internal device addresses (LS area/USRS area).

  • If the Device ID Address stores a device ID with no associated device/PLC, the parts set to the indirect device will not work.

Initial ID

Right after the display unit is turned ON and the value in the [Device ID Address] is 0, use this field to specify which device/PLC to use from 1 to 128.

Update Indirect Device Settings

Displays the [Update Indirect Device Settings] dialog box. If you change individual device settings after changing indirect devices, use this dialog box to update selected indirect devices with the new device/PLC settings.

Indirect Device Configuration

Displays the [Indirect Device Configuration] dialog box. Use this dialog box to check the association between indirect devices, devices/PLCs, and device IDs.