1.5.6.1 For Those Using GP-4100 Series

GP-4100 Series includes color and monochrome models. This manual uses the following descriptions.

Notiations in this manual

Model

GP-4100 Series (Color Model)

GP-4114T / GP-4115T / GP-4116T (hereafter referred to as GP-411*T.)

GP-4115T3 (hereafter referred to as GP-411*T3.)

GP-4100 Series (Monochrome Model)

GP-4104 / GP-4105 / GP-4106 / GP-4107 (hereafter referred to as GP-410*.)

GP-4100 Series

Refers to both Color Model and Monochrome Model

 

When using GP-4100 Series (Color Model)

Special Features

Unsupported Parts and Features

Limitations for Parts and Features

 

Special Features

GP-4100 Series (Color Model) has the following features.

As the GP-411*T is not equipped with backup memory, part of the internal memory is used as the backup area. User documents refer to this area as "virtual backup memory". Data in virtual backup memory, just like backup memory (SRAM), is preserved even when the display unit is turned off or restarted. You can check the virtual memory usage. From the [Project (F)] menu, point to [Information (I)], select [Project Information (I)], and then select [SRAM Information].

Unsupported Parts and Features

The following are parts and features unsupported by GP-4100 Series (Color Model).

Limitations for Parts and Features

On the GP-4100 Series (Color Model), some of the following parts and functions have limitations and differences depending on the model.

Part / Feature

Other Items / Limitations

Switch Lamp

  • Cannot output to AUX port.

  • Get operation log differs between models.
    GP-411*T: Cannot get operation log.
    GP-411*T3: Can get operation log.

Picture Display

  • You cannot use features that require a SD Card.

D-script

Common Settings [Global D-Script]

Common Settings [Extended Script]

  • When communicating with external equipment, even if you set the communication format to RS232C you cannot set up the 5V power supply.

  • Cannot use the following programming functions.

  • [SD File Operation]-Delete File, Output File List, Read File, Read CSV File, Change File Name, and Write File

  • [Others] - Start Application and Exit WinGP

  • [Label Settings]PRN_CTRL, SD_FILELIST_NUM, SD_READ_NUM, SD_ERR_STAT

[Alarm]

  • Memory for saving alarm history data differs between models.
    GP-411*T: Saves to virtual backup memory.
    GP-411*T3: Saves to backup memory.

  • When using GP-411*T, you can also define the interval at which alarm history data is saved to virtual backup memory.
    20.12.1.1 Alarm Guide

Common Settings [Sampling]

  • Whether sampled data is saved differs between models.
    GP-411*T: Does not save to virtual backup memory. Turning off the display unit erases the data.
    GP-411*T3: Saves to backup memory.

Common Settings [Recipe]

  • Memory for saving filing data differs between models.
    GP-411*T: Run [Prepare Transfer] to save to virtual backup memory.
    GP-411*T3: Saves to backup memory.
    26.11 Filing Data Flow

Common Settings - Start Screen Settings

  • You cannot set up [Display progress bar at startup].

System Settings [Display Unit]

  • In the [Operation Settings] tab, whether you can set up [Backup Internal Device] differs between models.
    GP-411*T: You cannot set up.
    GP-411*T3: You can set up.

 

When Using GP-4100 Series (Monochrome Model)

Special Features

Unsupported Parts and Features

Limitations for Parts and Features

 

Special Features

Unsupported Parts and Features

The following are parts and features unsupported by GP-4100 Series (Monochrome Model).

Limitations for Parts and Features

Support for the following parts and features is limited on GP-4100 Series (Monochrome Model).

Part / Feature

Other Items / Limitations

Switch Lamp

  • Cannot output to AUX port.

  • Cannot get operation log.

  • You can use only the following Special Switches.

  • Window Display Switch

  • Alarm History Switch (except switches you cannot set up in an alarm part)

  • Historical Trend Graph Switch

  • Security (log on, log off)

  • Operation Lock (supported by GP-4104 only)

  • Start Monitor Switch (Device Monitor)

  • Reset

  • Offline

  • Transfer Device/PLC Data

Data Display

  • You cannot define the position of the system keypad.

  • Cannot get operation log.

  • From the [System Settings], [Display Unit], in the [Display] tab you cannot use the [Synchronize Text Display language with Text Table] option.

Keypad / Key Parts

  • From the [Package] window, you can use the [DEC Keyboard] keypads only.

  • You cannot use Key parts for the Front End Processor (FEP) or AUX output.

  • You cannot connect a USB keyboard.

  • When using text keypads, you may have to touch a key multiple times to determine the character you want to enter.

Historical Trend Graph

  • Cannot use the [Display Historical Data] tab's [Show Cursor] and the [Time Display] tab's [Selected Time] options.

  • Cannot zoom in and zoom out.

Alarms

  • You cannot use [Scroll], [Refine Search/Sort], [Alarm Analysis], and [Start Ladder Monitor] operation switches.

  • Cannot use the Summary display.

  • Cannot set up animation.

  • Cannot use Multiple Line Display for alarm messages.

  • Cannot use the Sub Display's [Text Display Change] or [Movie] Modes.

  • You cannot select the [Item] tab's [Address] options.

Message Display

  • Cannot use Bulletin Messages.

Window Screens

  • Cannot set up [Disable touch outside windows].

  • You can edit the window size and display position in 1 pixel units.

Picture Display

  • You cannot use features that require a CF Card.

Trigger Action

  • Cannot use Special Actions.

D-script

Common Settings [Global D-Script]

Common Settings [Extended Script]

  • When communicating with external equipment, even if you set the communication format to RS232C you cannot set up the 5V power supply.

  • Cannot use multiple data formats in the same script.

  • Cannot use the following programming functions.

  • Extended Script - [File Operation] copy file

  • [CF File Operation] and [USB File Operation] - Delete File, Output File List, Read File, Read CSV File, Change File Name, Write File, and Label Settings

  • [Printer Operation] - Send and Label Settings

  • [Others] - Start Application and Exit WinGP

  • [SIO Port Operation] - functions in [Label Settings]: CF_ERR_STAT, CF_FILELIST_NUM, CF_READ_NUM, USB_ERR_STAT, USB_FILELIST_NUM, USB_READ_NUM, PRN_CTRL, PRN_STAT

Common Settings [Alarm]

  • Alarm history data is saved to virtual backup memory.

  • In the [Alarm Type], cannot select the [Extended] option.

  • Cannot get the data value associated with an alarm message.

  • Cannot use Multiple Line Display for alarm messages.

  • Cannot use the Summary display.

  • Cannot print.

  • Cannot output to a CSV file.

  • You can define the frequency of saving alarm history
    20.12.1 Common Settings (Alarm)

Common Settings [Sampling]

  • Cannot save to virtual backup memory. Turning off the display unit erases sampled data.

  • Cannot print.

  • Cannot write calculated data to internal devices.

Common Settings [Recipe]

  • Cannot transfer recipes (CSV data).

  • Cannot save filing data to an external storage.

  • [Preparing Transfer] saves filing data to virtual backup memory.
    26.11 Filing Data Flow

Common Settings (Symbol Variables) Settings Guide

  • Available only when using [Word Address] or [Bit Address]. Cannot use variables.

Common Settings [Text Table]

  • Cannot use [Expand index count].

  • From the [Utility] menu, cannot use [Create Display Unit File].

  • From the [System Settings], [Display Unit] link, in the [Extended Settings] tab's [Load Text Table] area, cannot use [Enable Load Text Table].

Common Settings [Security]

  • Cannot export passwords.

  • In the [Set Security Level For Each Feature], you can use [Offline Mode] only.

Font

  • Cannot use [Anti-alias] with image fonts.

  • Cannot set up fixed sizes for Standard Font.

  • From the [System Settings], [Display Unit], in the [Extended Settings] tab's [Compatibility] dialog box, you cannot use the [Draw Using Standard Font] option.

Bar Code

  • You can set up only one bar code reader.

  • You can use only USB-connected bar code and two-dimensional code readers. When connecting a bar code reader to the display unit, make sure you supply the bar code reader with an external power source (such as self-powered USB hub). The display unit cannot supply power. Otherwise the display unit could reset.

System Variable

  • Among HMI system variables, you can use only variables associated with features supported by the display unit. Cannot use logic system variables.

Animation

  • You can use Visibility Animation only.

Device Monitor

  • Cannot use monitor word block and monitor bit block.

  • Window size is fixed at 200x80.

  • Cannot minimize or move the window.

  • Cannot simultaneously monitor multiple equipment.

  • You can display up to 12 characters in an address.