25.11.9 Write Data

Select the settings for writing sampling data to the internal device of the display unit. For more information about this function, please refer to the following.

25.14.7 Writing to the Internal Device

Sampled Data

Write

Specify whether you want to write sampling data to the display unit's internal device.

Write Trigger Bit Address

Set the address to control data writing to internal device addresses. When the bit address is set to ON, sampling data is sent to the internal device.

Specify Write-To Block Number

If in the [Mode] tab's Extended area the [Overwrite old data after finishing the specified cycles] check box is cleared, designate whether or not to set the block number to write to the internal device.

Block Number Storage Word Address

When [Specify Write-To Block Number] is designated, set a word address in order to store the block number. The data stored in this address block will be outputted to the internal device.

If no block number is specified, data from Block Number "0" will be outputted.

Write-To Internal Device Word Address

Select the internal device address where the data will be stored. The sampling data will be stored starting from this address.

25.14.7.1 Writing to the Internal Device

Write Completion Bit Address

Designate whether or not to confirm the completion of writing to the internal device. If you want to confirm it, set a bit address. When the data write is finished, this bit will turn ON.

  • This bit will not be turned OFF automatically. After confirming that the writing was completed, please turn OFF this bit.

Include Number of Cycles

Designate whether or not to output the number of data sampled to the internal device along with the data.

Calculated Data

Write

Select whether or not to read total values for each data column, set on the [Display/Save in CSV] tab, to the internal device.

Write Trigger Bit Address

Set the address to control the writing of calculation data to the internal device. When this bit address turns ON, the calculation values for each Data column set on the [Display/Save in CSV] tab are written to the internal device.

Specify Write-To Block Number

If in the [Mode] tab's Extended area the [Overwrite old data after finishing the specified cycles] check box is selected, designate whether or not to set the block number to write to the internal device.

Block Number Storage Word Address

When [Specify Write-To Block Number] is designated, set a word address in order to store the block number. The totals data stored in this address block will be outputted to the internal device.

If no block number is specified, totals data from block number [0] will be outputted.

Write-To Internal Device Word Address

Select the internal device address where the totals data will be stored. The calculation data will be stored starting from this address.

25.14.7.1 Writing to the Internal Device

Write Completion Bit Address

Designate whether or not to confirm the completion of calculation data writing to the internal device. If you want to confirm it, set a bit address. When the data write is finished, this bit will turn ON.

  • This bit will not be turned OFF automatically. After confirming that the writing was completed, please turn OFF this bit.