GP-Pro EX Device/PLC Connection Manual
>>>Printing out the Device/PLC Connection Manual

YASKAWA Electric Corporation

The following table lists the YASKAWA Electric Corporation PLCs, and drivers that are supported by GP-Pro EX.

For details about how to connect to the Display, click the hyperlink in the Driver column to open the manual PDF (portable document format) file for that driver.

Refer to [Pass-Through Function Guide] after checking the system requirements in case to use the pass through function with GP-Pro EX.

When MP Series Ethernet (Extension) Driver is used, the GP-Pro EX Device Data Copy Tool is available. For details, refer to [Device Data Copy Tool Guide.]

Refer to the “MP Series (Extension) Driver” for the difference between MEMOBUS Driver (MEMOBUS SIO Driver / MEMOBUS Ethernet Driver) and MP Series (Extension) Driver (MP Series SIO (Extension) Driver / MP Series Ethernet (Extension) Driver).

Serial

Series

CPU

Link I/F

Driver

Control Pack

CP-9200SH

CP217IF (CN1, CN2, CN3)

MEMOBUS SIO

CP-9200

CP-9200H

CPU unit (PORT)

MP900

MP920

CPU unit (PORT1, PORT2)

CP217IF (CN1, CN2, CN3)

MEMOBUS SIO

MP930

CPU unit (PORT1, PORT2)

MP940

CPU unit (PORT1, PORT2)

MP2000

MP2200

MP2300

MP2310

MP2300S

Serial port on 218IF-01

Serial port on 218IF-02

Serial port on 217IF-01

Serial port on 260IF-01

Serial port on 261IF-01

MEMOBUS SIO

MP Series SIO (Extension)

Cf.MP Series (Extension) Driver

RS422/485 on 217IF-01

MEMOBUS SIO

MEMOCON GL

GL120

MEMOBUS port1,2 on CPU10 unit

MEMOBUS port on CPU20 unit

MEMOBUS port on CPU21 unit

JAMSC-120NOM26100

JAMSC-120NOM27100

MEMOBUS SIO

GL130

MEMOBUS port on CPU30 unit

MEMOBUS port on CPU35 unit

JAMSC-120NOM26100

JAMSC-120NOM27100

MEMOCON SC

U84,84J

JAMSC-C8110

MEMOBUS SIO

U84S

JAMSC-C8610

GL40S

JAMSC-IF61

JAMSC-IF41A

GL60H

GL70H

JAMSC-IF60

JAMSC-IF61

GL60S

JAMSC-IF60

JAMSC-IF61

JAMSC-IF612

MEMOCON Micro

Micro

CPU unit (PORT)

MEMOBUS SIO


Ethernet

Series

CPU

Link I/F

Driver

MP900

MP920

CN1(10BASE-5) on 218IF

MEMOBUS Ethernet

MP2000

MP2300

MP2200

Ethernet port on 218IF-01

Ethernet port on 218IF-02

MEMOBUS Ethernet

MP Series Ethernet (Extension)

Cf.MP Series (Extension) Driver

MP2310

MP2200S

Ethernet port on CPU unit

Ethernet port on 218IF-01

Ethernet port on 218IF-02

MEMOBUS Ethernet

MP Series Ethernet (Extension)

Cf.MP Series (Extension) Driver

MP2400

Ethernet port on CPU unit

MEMOBUS Ethernet

MP Series Ethernet (Extension)

Cf.MP Series (Extension) Driver


Inverter

Series

Inverter

Link I/F

Driver

Varispeed F7

CIMR-F7Aoooo

Terminal Block on the inverter

Inverter SIO

Varispeed G7

CIMR-G7Aoooo

Terminal Block on the inverter

VS mini J7

CIMR-J7oAoooo

Terminal Block on the
SI-485/J7 RS-422/485 interface card

VS mini V7/
VS-606V7

CIMR-V7oAoooo

Terminal Block on the inverter

Varispeed F7S

CIMR-F7Soooo

Terminal Block on the inverter

Varispeed L7

CIMR-L7Boooo

Terminal Block on the inverter

Varispeed AC

CIMR-ACAoooo

Terminal Block on the inverter

V1000

CIMR-VAoAoooo

Terminal Block on the inverter

J1000

CIMR-JAoAoooo

Terminal Block on the
SI-485/J RS-422/485 interface card


MP Series (Extension) Driver

When using the Pass Through Function or the devices below, use the MP Series (Extension) Driver.  These functions and areas cannot be used with the MEMOBUS Driver.

  • S Register (SW00000 - SW08191)

  • O Register (OB00000 - OB7FFFF, OW0000 - OW7FFF)

  • Parameter of Motion Series (IW8000 - IWFFFF、OW8000 - OWFFFF)

  • Extension of M Register (Area of MB40960 - MB65534F and MW32768 - MW65534 can be used.)

The following restrictions only apply to the MP Series (Extension) Driver and not to the MEMOBUS Driver.

  • Communication speed becomes slower compared to the MEMOBUS Driver.

  • MP Series SIO (Extension) Driver allows only one unit to be connected.

  • SIO type of the MP Series Ethernet (Extension) Driver is only Ethernet (UDP).

note

When connecting to an Ethernet, effective communication can be obtained by using both the MEMOBUS Ethernet Driver and the MP Series Ethernet (Extension) Driver.


Outline

Connect 2 drivers, MEMOBUS Ethernet Driver and MP Series Ethernet (Extension) Driver, to the same connection device.  Since the MEMOBUS Ethernet Driver is faster than the MP Series Ethernet (Extension) Driver, it is recommended that devices capable of using the MEMOBUS Ethernet Driver to use it, and for devices incapable of doing so to use the MP Series Ethernet (Extension) Driver so as to maximize efficiency.


Setting

GP-Pro EX sets 2 drivers.  Set the MOMOBUS Ethernet to External Device 1, and set the MP Series Ethernet (Extension) to External Device 2.  Setup each with the following points in mind.

  • Set [Port No.] of [Communication Settings] so that External Device 1 and 2 do not overlap.  To avoid duplication, we recommend that you set [Auto] to the port No. of External Device 2.

  • Set the same IP address to External Device 1 and 2 because [IP Address] of dialog box of [Individual Device Settings] accesses the same External Device.  We recommend that you set “MEMOBUS1” or “MP1”, etc. to [Device Name] of [Device-Specific Settings] for distinction.

How to Use

Select External Device to be used from [Device/PLC] when inputting address.

Select “MEMOBUS1” for the device that can be communicated with the MEMOBUS Ethernet Driver.  In the same way, select “MP1” for devices that can be communicated to by the MP Series Ethernet (Extension) Driver.