产品
下载
联系我们
网站地图
返回首页

微信扫一扫
在线技术支持

微信扫一扫
访问视频号

 FAQ

 What’s the Enhanced Recipe function?


The Enhanced Recipe function is one of three kinds of recipe functions.

You can directly transfer the recipe data (binary type) created on GP-Pro EX from the touch operator interface to the connected device and also can read out the data of the connected device and save them in the touch operator interface.

 
 
There are differences between the Enhanced Recipe function and the other recipe functions as shown below.
 
Recipe Function
Type
Enhanced Recipe
Filing Data Transfer
CSV Data Transfer
Creating data GP-Pro EX
Spreadsheet Software
(Excel etc)
GP-Pro EX GP-Pro EX
Spreadsheet Software (Excel etc)
Data Type - Data created on GP-Pro EX (binary type)
- CSV File *1,*2
Data created on GP-Pro EX (binary type) CSV File
How to change data - Edit on GP-Pro EX
- Edit on Touch Operator
  Interface *3
- Edit on GP-Pro EX
- Edit on Touch Operator
  Interface
- Edit on GP-Pro EX
- Edit on Touch Operator
  Interface
Data Type to be
handled
- Word
 16 bits/32 bits
 Dec/Hex/BCD/Float
- Bit
- Text
Word
16 bits/32 bits
Dec/Hex/BCD/Float
Word
16 bits/32 bits
Dec/Hex/Float
Mixed data type
-
-
Address Setup
Sequential/Random address
Sequential address only
Sequential address only
Using data for
other projects
*4
-
Refine Search/Sort
on Touch Operator
Interface
*5
-
-
*1: A SD card or a USB storage device is required.
*2: The CSV file setting in the SD card/the USB storage device cannot be directly imported to the GP-Pro EX project file. In order to reflect the setup values in the CSV file into the project file, you need to import the CSV file to the internal memory of the touch operator interface once and then receive the project file of the touch operator interface.
*3: Display the keypad on the touch operator interface and edit data, or import data from the SD card/the USB storage device and change data.
*4: Possible by importing the exported CSV file to the touch operator interface’s internal memory. The Enhanced Recipe settings (the number of elements, the data type) should be the same.
*5: Except GP-4*01TW and GP-4401WW
 
返回页面顶端 返回上一页
常见问题 | 个人信息保护 | 关于知识产权 | 使用条款
版权 (C) 2005- Schneider Electric Japan Holdings Ltd.,和普洛菲斯国际贸易(上海)有限公司版权所有,保留所有权利。
沪ICP备05028659号-3