 I would like to keep the data of symbol variables even after the power is turned off.

Please check [Keep] ON for symbol variables to keep the current variable data even after the power is turned off.



MEMO
Keep/Clear Variables
1.
Please refer to the default settings for Keep/Clear points as below.
Symbol Variable
Default Settings
For Address Format
Keep
Clear
Bit Variable
4000 pts
4000 pts
M_
Integer Variable
4000 pts
4000 pts
D_
Float Variable
64 pts
64 pts
F_
Real Variable
64 pts
64 pts
R_
Timer Variable
256 pts
256 pts
T_
Counter Variable
256 pts
256 pts
C_
Time Variable
32 pts
32 pts
J_
Date Variable
32 pts
32 pts
N_
PID Variable
8 pts
0 pts
U_

2.
It is possible to specify the variable points to keep or clear on [Keep Area Settings].