 Sample of Up Counter Settings
Set the preset value on the screen, and create the counter to pass power when it gets the preset value of Pulse Input by counting up.


1. Place the Up Counter on Logic Program.

A.
Set the specified variable (e.g.; Up Counter) on the placed Up Counter.

B.
Place "Coil Output" which will be ON when the current value of the counter gets the preset value, and set the specified variable (e.g.; Output).

C.
Place "Positive Transition" to provide Pulse, and set the specified variable (e.g.; Input).

D.
Place Normally Open to reset the current value of the counter, and the specified variable (e.g.; Reset Switch).
Also place the coil which has been allocated Conter Reset Bit (Up Counter. R) ahead of Normally Open.



2. Place the Data Display on the screen, and allocate the variable "PV (e.g.; Up Counter. PV)", which you have set on "CTU", to Monitor Word Address.



3.
Place the Bit Switch on the screen, and allocate the variable (e.g.; Reset Switch), which you have set on "NO (Normally Open)", to Bit Address.



Settings completed.