37.17.1 Procedure - Limiting Camera-Viewer EX Users (Security) with Levels

Registers passwords for security levels 1 to 15 and defines the security level for each display screen. In the following example, an operator with Level 15 security can use Camera-Viewer EX.

  1. In GP-Pro EX, from the [Common Settings] menu point to [Security] and select [Security Password], or click .

  2. The [Set password] screen opens. Select the [Enable Security Function] check box, and type the password "5555" in [Level 15].

    • Each password should be 8 single-byte characters or less.

  3. Select the [Set Security Level For Each Feature] check box, then set the [Read Camera Viewer] level to 15.

    • After setting up security levels, transfer the project to the display unit.

    • For information about Camera-Viewer EX security operations, please refer to the Camera-Viewer EX Operation Manual, Procedure - Limiting Camera-Viewer EX Users (Security).