GP-Pro EX Device/PLC Connection Manual
Please see below for required drivers and the system requirements to use the pass-through function.
Please refer to [Pass-Through Function Guide] for installation or settings of the pass-through function.
When using the Pass-Through Function by SIMATIC S7 MPI Direct Driver, please refer to [SIMATIC S7 MPI Direct Driver Pass-Through Function Guide].
For details about how to connect to the Display, click the hyperlink in the Driver column to open the manual PDF (portable document format) file for that driver.
Maker |
Driver |
System Requirements |
---|---|---|
Mitsubishi Electric Corporation |
The following GPP function software packages are required. Windows XP: Windows Vista: Windows 7: Windows 8: Windows 8.1: When using iQ-R/F Ethernet(SLMP Client), the following limitations apply. - Pass-Through Function can be used only when the display is connected to the Ethernet Port on CPU unit. - You cannot connect External Devices from the same series (iQ-R or iQ-F) at the same time. However, you can connect 1 device each from iQ-R and iQ-F series at the same time. - Set up 120 secords or more for GX Works3's [Check at Communication Time]. Additionally, set the GP-Pro EX [Timeout] to 60 seconds or more. - When using a hub, GX Works3 may generate the following error, "Unable to communicate with PLC." |
|
YASKAWA Electric Corporation |
The following engineering tool is required. MPE720 Ver5.38 / Ver6.04 or higher |
|
The following engineering tool is required. MPE720 Ver5.38 / Ver6.04 or higher - When GP-3200 series, GP-3300 series, and LT3000 series are connected with the MP3000 series, the ladder program cannot be read out with the pass-through function. - If a communication error occurs in the engineering tool while using the pass-through function, increase the amount of time in the driver's [Timeout] field. |
||
Yokogawa Electric Corporation |
The following programming tool is required. WideField2 R3.01 or higher - Pass-Through Function can be used only when the display is connected to the programming port on the CPU. - Windows 7 (64 bit) and Windows 8 (64 bit) are not supported. |
|
The following programming tool is required. WideField2 R3.01 or higher Windows 7 (64 bit) and Windows 8 (64 bit) are not supported. |
||
OMRON Corporation |
The following programming support tool is required. CX-Programmer Version 3.00 or higher To use Pass-Through Function, [SYSMAC WAY] needs to be specified for [Network Type] in the ladder software. |
|
The following programming support tool is required. CX-Programmer Version 3.00 or higher - If High Performance Unit is written by the Pass Through Function, response of Link Unit temporarily stops and an error may be displayed on the Display. - To use Pass-Through Function, [SYSMAC WAY] needs to be specified for [Network Type] in the ladder software. - The following CPU unit does not support the Pass-Through Function. CJ2H-CPU68-EIP CJ2H-CPU67-EIP CJ2H-CPU66-EIP CJ2H-CPU65-EIP CJ2H-CPU64-EIP CJ2M-CPU35 CJ2M-CPU34 CJ2M-CPU33 CJ2M-CPU32 CJ2M-CPU31 |
||
Rockwell Automation, Inc. |
The following programming support tools are required. RSLogix500 RSLogix5000 Windows 7 (64 bit) is supported only when RSLogix5000 is used. |
|
Siemens AG |
The following programming tools are required. SIEMENS SIMATIC SoftwareSTEP7 Version 5.1 or higher STEP7 - Micro/WIN Version 4.0.1.10 or higher SIMATIC S7-1200 Series does not support the Pass-Through Function. |
|
KEYENCE Corporation |
The following ladder support software is required. KV STUDIO: KV BUILDER: - During [Transfer to PLC] and [Read from PLC] on the Ladder Support Software, the communications with the Display may be temporarily interrupted. - When using the pass-through function, use the same value for the communication speed between the ladder software and the Display. - Windows 7 (64 bit) is supported only when KV STUDIO is used. |
|
Panasonic Industrial Devices SUNX Co., Ltd. |
The following programming tool software is required. Control FPWIN GR Ver.2.30 or higher - When using Pass-Through function, it is necessary to connect Display to Tool port of the control unit. - "C-NET (RS232C)" needs to be selected for [Network type] in the [Communication Settings]. - "Station home" or "C-NET" needs to be selected for [Network selection] in the [Specify Station No.]. However, select "C-NET" when you use Control FPWIN GR Ver. 2.30. - During [Upload from PLC] and [Download to PLC] on the Programming Tool Software, the communications with the Display may be temporarily interrupted. |
|
TOSHIBA MACHINE CO.,LTD. |
The following programming software is required. Windows XP: Windows 7: - In the 1:n connection, the Eternal Device to be connected with is specified using the programming software. For a Pass-Through configuration tool, specify the External Device directly to be connected. - Please refer to TOSHIBA MACHINE CO.,LTD. for the model that can use the Pass-Through Function. |