37.2.1 Operation Environment - GP-Viewer EX

GP-Viewer EX runs on the following computer environments.

Items

Required Specifications

PC

Windows® PC/AT compatible machine

Operating System

  • All editions of Windows 7
    32-bit/64-bit versions

  • All editions of Windows Vista
    32-bit version

  • All editions (Service Pack 2 or later) of Windows XP
    32bit version

  • Windows 2000
    (Service Pack 3 or later)

  • All editions (Service Pack 2 or later) of Windows Server 2003
    32-bit version

CPU

Pentium IV, Pentium M (1.5 GHz or higher recommended)

Memory

  • Windows 7, Windows Vista
    1 GB or higher (2 GB or higher recommended)

  • Other than Windows 7 or Windows Vista
    256 MB or higher (512 MB or higher recommended)

Hard Disk Space

150 MB or higher (this amount of free space is required for the installation)

Resolution

1024x768 or higher

Language

[ASCII], [Japanese], [Chinese (Traditional)], [Chinese (Simplified)], or [Korean].

(To use any language other than Japanese or Latin-based languages, you need to add the corresponding fonts and FEP.)

Required equipment

  • Use a mouse (compatible with the OS mentioned above).

  • CD/DVD drive
    Only required when installing

 

Difference between GP-Viewer EX and Display Units

Feature

Details

Switch

  • AUX Output cannot be used.

  • Special switches related to security, resetting, offline or other unsupported features cannot be used.

  • If switches overlap, or multiple switch functions are set up, operations may differ from the display unit.

Sampling Display

  • You cannot edit data.

  • First gets all sampling information, and then updates at the frequency specified in GP-Viewer EX. From the [Tool] menu click [Settings] and note the [Update Cycle] field.

  • Refine Search/Sort is available, but it does not synchronize with the display unit.

Alarm feature

  • The Sub Display feature may be executed at an unexpected time by operation on the display unit even when the Alarm part is not displayed.

  • Alarm information cannot be cleared by external operation.

  • Display content may be displayed differently than the display unit (time information, active alarm status, and so on). Touching the [Screen Update] button will update the contents by re-acquiring the alarm information.

  • You cannot save alarm information.

  • You cannot perform [Acknowledged] or [Clear] operation.

  • You cannot perform [Alarm Number Acquisition] operation.

  • If alarm analysis is used, the analysis list is not shown on the operation log.

  • Refine Search/Sort is available, but it does not synchronize with the display unit.

Logic Programing

Global D-Script

Extended Script

You can review the results processed on the display unit, but the results of drawing are not reflected.

D-script

This feature is enabled in Synchronous Mode. However, the results of drawing are not reflected.

This feature may be executed even in Asynchronous Mode when the same screen is displayed.

Trigger Action

  • This feature is executed in Asynchronous Mode when the same screen is displayed. In this case, changing screens on the display unit does not change screens in GP-Viewer EX. Therefore, execution of [Start Application] or [Exit WinGP] cannot be confirmed by GP-Viewer EX, so do not perform such operations from GP-Viewer EX.

  • This feature is enabled in Synchronous Mode. However, the results of drawing are not reflected.

Screen Capture

  • The screen of the display unit cannot be captured with Screen Capture Settings. This should be performed from [Screen Capture] in the [Tools] menu.

Error

  • Displays errors on both the display unit and GP-Viewer EX.

  • All errors are acquired at first and then the information is updated at the frequency specified in GP-Viewer EX. Click [Change setting] and select [Information of Automatic update frequency].

  • Errors that are restored will not disappear. Such errors disappear only when the screen is changed.

Data Display

  • In Numeric Display or Text Display, when [Device Type Address] is specified for Address Type and a device (PLC) is used for Monitor Word Address, an error occurs.

Historical Trend Graph

  • You cannot review Cursor Information Storage Address, Status Address and Search Status of the Viewer.

Data Block Display Graph

  • In Asynchronous Mode, select [Block Display Graph] from the [Update (U)] menu to clear or redisplay the graph. Follow the same procedure when update does not happen in Synchronous Mode.

XY Historical Scatter Graph

  • Immediately after changing screens, all the data in the buffer is displayed on a graph, including the previously sampled data.

XY Block Display Scatter Graph

XY Historical Scatter Graph Normalization

  • When quickly changing the control word using D-Script or a PLC with ladder logic on the display unit, server operations may not be detected.

  • In Asynchronous Mode, when updating the graph, its Display Completion bit does not turn ON. Therefore, the control word cannot be returned to 0 on the display unit. Prior to updating, create a switch that returns the control word to 0.

Bulletin Message

  • When you perform a display/hide operation continuously, display contents may not be synchronized with the display unit.

  • In order to update the message, clear the message and display it again.

  • Display Completion bit cannot be used.

Recipes

  • The recipe feature does not work.
    Special Data Display (Data Transmission, Filing and Show CSV) is not displayed.

Enhanced Recipes

  • The enhanced recipe feature does not work.
    The Enhanced Recipe List and Enhanced Recipe Data List are not shown.

File Manager

  • Status Address and Select Movie cannot be set.

  • Files in the GP-Viewer EX computer are displayed.

LS Area

Memory Link

  • You cannot write data in the Special Relay Area (LS2071 to LS2074, LS2078 to LS2095) from the Viewer.

  • Write operation into Special Relay Area and Extend System Area is not supported.

Security Level Clear

  • To change or clear the level, from the Menu, point to Feature, and select Change Security Level or Change User ID.
    You can set the security level to 0 if you leave the user ID/password field blank and press the OK button. (This cannot be completed when the security is set for reading Viewer data.)

Standby Mode

  • The screen does not change to the standby mode.
    The display unit will switch to standby mode, but the screen will not be changed while the Viewer is connected.

Japanese FEP (Help)

  • Dictionary information registered on the display unit cannot be used.

Cursor Information Storage Address

Status Address

Search Status Address

  • Information on the items shown on the left for each part/feature cannot be obtained.

Operation Log

  • An operation log file is not saved.

Web Server and FTP Features

  • Web Server and FTP Features do not work.

Monitor

  • Logic Monitor, Ladder Monitor, Device Monitor, VM/DVI and RPA do not work.

RPA Function

  • RPA feature cannot be used.

Printing feature

  • The printing feature does not work.

Transfer Project File

  • Project files cannot be transferred.

Monitor

  • Device Monitor, Address Monitor and Ladder Monitor cannot be used.

2-color Backlight Switching

  • 2-color Backlight Switching cannot be used.

Brightness and Contrast

  • You cannot adjust the brightness and contrast.

Offline mode

  • Cannot change to offline mode.

Bar Code Reader

  • A bar code reader cannot be connected.

Modem

  • Cannot be connected to a modem.

Hand-held type GP function key

  • Hand-held GP function keys cannot be operated.

Playing Movies

  • You cannot record or play movies.

  • The Movie Player cannot display.

Image Unit Features

  • Image Unit Display cannot display.

Image Sensor Display

  • Does not display a picture.

Checking tag consistency

  • You cannot check tag consistency.

Others

  • Does not respond to the station search of Pro-Server EX.

  • The time displayed on GP-Viewer EX is based on the time settings of your computer.