You can drag the following parts from the instructions or operands in the Logic and drop on the drawing screen to allocate or reallocate the symbol variables.
Do not place real-type variables or instructions that have real variables as parts in operands. It will not display properly.
Drag & Drop Instructions and Operands |
Parts that can be allocated or parts to which a new symbol variable can be placed |
|||
---|---|---|---|---|
Instruction |
Number of Operands |
Symbol Variable Type |
||
Basic Instructions |
||||
NO, NC, PT, NT |
1 |
S1 |
Bit Address |
Bit Switch |
Bit Variable |
||||
OUT, OUTN, SET, RST, PTO, NTO |
1 |
D1 |
Bit Address |
Lamp |
Bit Variable |
||||
JMP, JSR |
1 |
— |
— |
— |
RET, EXIT |
— |
— |
— |
— |
FOR |
1 |
S1 |
Word Address |
Data Display |
Integer Variable |
||||
NEXT |
— |
— |
— |
— |
PBC |
2 |
S1 |
— |
— |
D1 |
Bit Variable |
Lamp |
||
PBR |
1 |
S1 |
— |
— |
Operation Instructions |
||||
ADD, SUB, MUL, DIV |
3 |
S1 |
Word Address |
Word Switch Data Display (You cannot select the Word switch for float variables and real variables.) |
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
MOD |
3 |
S1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
JADD, JSUB |
3 |
S1 |
Time Variable (.HR .MIN .SEC) |
[Variable: Integer Variable] Word Switch Data Display |
S2 |
Time Variable (.HR .MIN .SEC) |
|||
D1 |
Time Variable (.HR .MIN .SEC) |
|||
AND, OR, XOR |
3 |
S1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
NOT |
2 |
S1 |
Word Address |
|
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
MOV |
2 |
S1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
BLMV |
3 |
S1 |
Bit Address (Array) |
Word Switch Data Display (You cannot select S1 or D1.) |
Integer Variable (Array) |
||||
Float Variable (Array) |
||||
Real Variable (Array) |
||||
S2 |
Integer Variable |
|||
D1 |
Bit Address (Array) |
|||
Integer Variable (Array) |
||||
Float Variable (Array) |
||||
Real Variable (Array) |
||||
FLMV |
3 |
S1 |
Word Address |
Word Switch Data Display
(You cannot select D1.) |
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
S2 |
Integer Variable |
|||
D1 |
Integer Variable (Array) |
|||
Float Variable (Array) |
||||
Real Variable (Array) |
||||
XCH |
2 |
D1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
D2 |
Word Address |
|||
Integer Variable |
||||
ROL, ROR, RCL, RCR, SHL, SHR, SAL, SAR |
3 |
S1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
Compare Instructions |
||||
EQ, GT, GE, LT, LE, NE |
2 |
S1 |
Word Address |
Word Switch Data Display (You cannot select the Word switch for float variables and real variables.) |
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
JEQ, JGT, JGE, JLT, JLE, JNE |
2 |
S1 |
Time Variable (.HR .MIN .SEC) |
[Variable: Integer Variable] Word Switch Data Display |
S2 |
Time Variable (.HR .MIN .SEC) |
|||
NEQ, NGT, NGE, NLT, NLE, NNE |
2 |
S1 |
Date Variable (.YR .MO .DAY) |
[Variable: Integer Variable] Word Switch Data Display |
S2 |
Date Variable (.YR .MO .DAY) |
|||
Timer Instructions |
||||
TON, TOF, TP, TONA, TOFA |
1 |
Variable |
Timer Variable (.ET .PT) |
[Variable: Integer Variable] Word Switch Data Display |
Timer Variable (.Q .TI .R) |
[Variable: Bit Variable] Bit Switch Lamp |
|||
Counter Instructions |
||||
CTU, CTD, CTUD |
1 |
Variable |
Counter Variable (.PV .CV) |
[Variable: Integer Variable] Word Switch Data Display |
Counter Variable (.Q .QD .QU .UP .R) |
[Variable: Bit Variable] Bit Switch Lamp |
|||
Convert Instructions |
||||
BCD, BINENCO, DECO |
2 |
S1 |
Word Address |
Word Switch Data Display |
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
RAD, DEG, SCL |
2 |
S1 |
Word Address |
Word Switch Data Display (You cannot select the Word switch for float variables and real variables.) |
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
Float Variable |
||||
Real Variable |
||||
I2F, I2R, F2I, F2R, R2I, R2F, H2S, S2H |
2 |
S1 |
Type |
|
— |
||||
D1 |
Type |
|||
Function Instructions |
||||
SUM, AVE |
3 |
S1 |
Integer Variable (Array) |
Word Switch Data Display (You cannot select S1.) |
Float Variable (Array) |
||||
Real Variable (Array) |
||||
S2 |
Integer Variable |
|||
D1 |
Integer Variable |
|||
Float Variable |
||||
Real Variable |
||||
SQRT |
2 |
S1 |
Float Variable |
Data Display |
Real Variable |
||||
D1 |
Float Variable |
|||
Real Variable |
||||
BCNT |
2 |
S1 |
Integer Variable (Array) |
|
Float Variable (Array) |
||||
Real Variable (Array) |
||||
D1 |
Integer Variable (Array) |
|||
Float Variable (Array) |
||||
Real Variable (Array) |
||||
PID |
5 |
Variable |
PID Variable (.KP .TR .TD .PA .BA .ST) |
[Variable: Integer Variable] Word Switch Data Display |
PID Variable (.Q .UO .TO .PF .IF) |
[Variable: Bit Variable] Bit Switch Lamp |
|||
S1 |
Word Address |
Word Switch Data Display |
||
Integer Variable |
||||
S2 |
Word Address |
|||
Integer Variable |
||||
S3 |
Word Address |
|||
Integer Variable |
||||
D1 |
Word Address |
|||
Integer Variable |
||||
SIN, COS, TAN, ASIN, ACOS, ATAN, COT, EXP, LN, LG10 |
2 |
S1 |
Float Variable |
Data Display |
Real Variable |
||||
D1 |
Float Variable |
|||
Real Variable |
||||
R/W Instructions |
||||
JRD, JSET |
1 |
D1 |
Time Variable (.HR .MIN .SEC) |
[Variable: Integer Variable] Word Switch Data Display |
NRD, NSET |
1 |
D1 |
Date Variable (.YR .MO .DAY) |
[Variable: Integer Variable] Word Switch Data Display |