NOTE:
To use the Pro-server Ver. 3.12 functions, 2-Way Driver shoud, also,
be updated to Ver. 3.02. Click here to download
this file.
|
File
Name |
Pro-ServerV312.exe |
Size |
6,183KB |
Update
Version |
3.12 |
Original
Version |
Pro-Server
with Pro-Studio Ver. 3.0, Ver. 3.01,
Ver. 3.10, Ver. 3.11 |
Update
Description |
1.The
following errors were corrected. |
- |
Sometimes
data was not saved under the
designated file name. |
|
|
Action feature "Writes
Data to Excel Book." |
- |
When "Append
Data" was selected for the
data save type, existing log
data was overwritten by the newly
saved data. |
|
|
Action Feature "Upload
of GP Log Data." |
- |
When
Pro-Server Ver. 3.1 is installed,
the OPCPRO.EXE application would
not run. *1 |
- |
Action
Feature "Send Data via Mail" can
create garbage characters. |
- |
Pro-Studio
can be forced to shut down. |
2. The Remote RAS for PL Series is newly supported. |
- |
The
Remote RAS and Remote Shutdown
Programs are available
for free download. |
*1 To
prevent this from occurring,
please download "OPCServer312.exe".
After downloading is completed,
differential installation will
be performed. Instead of uninstalling
the OPC Server, simply perform
this installation.
If the OPC Server is not
installed on your PC, there
is no need to perform this
installation.
|
|
*This
applies to users who have performed
the Ver. 3.1 or later update. |
|
|
|
Opening the file: (This is a self-extracting
file.)
Since this installer only modifies existing Pro-Server code, Pro-Server Ver.
3.0 does not need to be uninstalled.
Prior to installing the update module, be sure to exit the Pro-Server program.
|
1. |
Click on the above file name to download the data
to a folder you wish to store. |
2. |
After the download is finished, double-click
on the file to open it. |
3.
|
Follow the Installer's instructions to install the
update files. |
4. |
After installing this module, restart your PC. |
Attention:
While viewing the property of the downloaded
update module, and selecting the "Version
Tab", the follwing error will be displayed:
"This program has performed an illegal operation and will be shut down."
We have confirmed this problem. Please do not view the "Version Tab" of
this updated module.
This problem will not effect the updated module which will correctly install
the updated files to your computer. |
|
Update
History:
[Ver. 3.11 Update Contents] Last
updated August 10, 2001 |
1. |
The following errors were
corrected.
- |
When the Action feature "Upload
of GP Log Data." is used, if
the data save format "CSV type" is
used and "Add data" is
used as the save type, all data uploaded
is simply written over the existing
Log data. |
|
|
[Ver. 3.10 Update Contents] Last
updated May 28, 2001 |
1. |
The Cache-Read Function speeds
up initial device readout. |
2. |
Writing to devices with no
cache is also faster. |
3. |
Previously unreadable devices
are now readable. |
4. |
Bit access to GLC 32-bit Devices
is now possible. |
5. |
The following errors were
corrected.
- |
During saving of CSV
data using "Upload of GP Log
Data." Action. |
- |
Excessive time required
to save data using "Upload of
GP Log Data." Action. |
- |
No data caused writing
to the next Excel sheet during use
of "Writes Data to Excel Book." Action. |
|
|
[Ver. 3.01 Update Contents]
Pro-Server's "Upload of GP Log Data." has been modified as follows. |
- |
Editing Pro-Server Ver. 2.0
data will not cause an error. |
- |
Uploaded Log data that contains
date information will not be overwritten
with incorrect data. |
- |
When a template is used, the
data write range no longer needs to be the
data item count + 1. |
|