Software Update Module / Add-on Software |
Error Contents |
1. |
While using the action
features of Pro-Server Ver. 2.0/3.0, Excel will display incorrect
dates when the GP's internal clock year becomes 2001.
Uploading actions for Logging, Alarm Log, Alarm History, and other data files
with dates will not be shown correctly on an Excel sheet.
This error will not occur on a file in the CSV format, but only on a file in
the Excel format.
|
|
Incorrect |
Correct |
1/1/2002
(January 1, 2002) |
1/2/2001
(January 2, 2001) |
1/1/2003
(January 1, 2003) |
1/3/2001
(January 3, 2001) |
1/1/2004
(January 1, 2004) |
1/4/2001
(January 4, 2001) |
|
1/1/2029
(January 1, 2029) |
1/29/2001
(January 29, 2001) |
1/1/2030
(January 1, 2030) |
1/30/2001
(January 30, 2001) |
|
|
|
2. |
Pro-Server Ver. 3.0 will
display an error message when opening Actions with created with
the action features of Pro-Server Ver. 2.0. |
|
[ERR=No.380,Invalid property value]
|
|
Opening the (data) file will not cause the error
message, but only after trying to view the settings. If the cancel
button on the Error dialog is selected, the data will disappear,
as if it was deleted.
The data is still there and can be used by Pro-Server, but the problem is that
it cannot be seen.
This is an error on the display programs on Pro-Server Ver. 3.0, and the previously
set actions can be performed without the display.
This is an error only on Pro-Server Ver. 3.0, and works correctly on Pro-Server
Ver.2.0. |
|
Last Updated: Dec.27,2000 |
|